Web orders only - FREE shipping via UPS Ground (continental US only, motor freight excluded)
 
 
 
 
 
  BRAKE PRODUCTS
65,940 part numbers: Brake Wheels & Discontinued Brake Parts
  GEMCO
14,192 part numbers: Motion Control Products
 
  GLEASON
17,994 part numbers: Cable & Hose Management Systems
  AERO-MOTIVE
3,646 part numbers: Cable & Hose Management Systems
  CUTLER-HAMMER
6,339 part numbers: Electrical Control Products
 
 
 
 
 
  STEARNS
6,655 part numbers: Motor Mounted Brakes
  HUBBELL
10,539 part numbers: Electrical Control Products
  SUPERBOLT
112 part numbers: Fastening Solutions
  TELEMOTIVE
2,488 part numbers: Radio Remote Control
  RENOLD
400 part numbers: Mechanical Power Transmission Products
 
 

Aero-Motive Direct
Amazon Store

 
68 part numbers
 

Brake Products
Amazon Store

 
473 part numbers
 
COVID-19 SUPPORT
Brake Products is open with a smaller staff and less hours as a Critical Supplier to the Steel Industry. We are doing our part to mitigate the spread of the virus by complying with the requests by our Federal and State Governments.
 
BPI has inventory and is ready to assist you with your required products and parts. Our priority is to keep U.S. Manufacturing running without delay. Call us at (440) 543-7962 or email us at sales@brakeproducts.com
 
We are ready to help.
 
John Hooper, President
Brake Products, Inc.
 
Web: www.stearns-direct.com Email: sales@stearns-direct.com Phone: (888) 861-8777
 
Brakes and Replacement Parts: P/N 8-078-905-28
Installation, Service and Parts List Series 56,800 for
Class I & II, Division 2 Manual Adjust Brakes Rev: C [P/N 8-078-905-28]


No Qty
Req'd
Item Part
Number
Description Picture Stock
Qty
Price
Each
Qty
Ord'd
Update
Cart
1 1 A STE-5-66-1015-00 Stearns Hardware Kit - side release - 0 $92.38
2 1 Not shown STE-5-63-0532-00 Stearns Plug/Gasket Kit 
Part 5-63-0532-00 
aka 563053200 
NEMA 4 
[Ships in 5 to 7 days] 
[Updated 1/19]
- 0 $29.20
3 1 Not shown STE-5-63-0534-00 Call - 0 Call Call Call
4 1 7 STE-5-07-5050-00 Call - 0 Call Call Call
5 1 5 STE-8-003-515-00 Call - 0 Call Call Call
6 1 3 STE-5-66-8354-00 Stearns Disc kit 
Part 5-66-8354-00 
Stationary Disc Kit  
Dated 1/18
- 0 $53.47
7 1 Not shown STE-5-63-0525-00 Stearns Spring Kit 
Part 5-63-0525-00 
aka 563052500 
56 Plug Wire Nut & Vertical Spring Kit-Open 
Ships from Stock to 5 Days 
Dated 1-2020
- 0 $53.95
8 1 4 STE-5-66-8462-00 Stearns Disc 
Part 5-66-8462-00 
aka 566846200 
Friction Disc with Splined Hub 
Normally Ships from Stock 
Dated 1-2020 
(22LBS) H 4" L 10" W 10" Box
- 1 $129.69
9 1 21 STE-9-62-8026-00 Stearns Thermostat - 0 $258.65
10 1 16 STE-5-16-5153-00-01B Stearns 56 spln. hub 5/8 bore 2&3 disc - 0 $78.52
11 1   STE-5-16-5153-00-01D Stearns Hub 
Part 5-16-5153-00-01D 
56K Splined Hub 
0.9875 Inch Bore 
2 & 3 Disc 
Ships in 10 Days 
Dated 12-19
- 0 $88.60
12 1   STE-5-16-5153-00-01E Stearns 56 spln. hub 1-1/8 bore 2&3 disc - 0 $101.61
13 1 2 STE-5-02-5049-00 Stearns End Plate / Seal Assembly 
Part STE-5-02-5049-00 
56,800 Div. 2, 1 Disc 
End Plate / Seal Assmbly 
Dated 1/17
- 0 $654.50
14 1   STE-5-02-5050-00 Stearns End Plate Seal Assembly 
Part STE-5-02-5050-00 
56,800 Div. 2, 2 & 3 Disc 
Endpalte / Seal Assembly 
Dated 1/17
- 0 $673.75
15 1 6 STE-8-006-501-00 Stearns Bearing 
Part 8-006-501-00 
aka 800650100 
Sleeve Bearing 
Oilite 
0.31 Inch Diameter  
0.59 Inch Long 
Ships in 
Dated 4-2020
- 0 $5.94
16 1 8 STE-8-008-504-01 Stearns Lever 
Part 8-008-504-01 
aka 800850401 
56 Solenoid Lever 
Aluminum W/Fin 
Ships in 10 Days, Racine WI 
Dated 1-2020 
(1LB) H 4" L 5" W 4" Box
- 0 $46.04
17 1 8R STE-9-03-0057-00 Stearns Retaining Ring 
Part 9-03-0057-00 
aka 903005700 
Dated 4-2020
- 0 $2.98
18 1 8W STE-9-45-0168-00 Stearns Lock Washer 
Part 9-45-0168-00 
Dated 1/17
- 0 $2.20
19 1 11N STE-9-40-3928-00 Stearns Nut - 0 $3.70
20 1 10 STE-9-17-8420-00 Stearns Cap screw - 0 $11.09
21 1 11 STE-9-70-1215-00 Stearns Pressure Spring 
Part 9-70-1215-00 
Ships in 
Dated 10/18
- 0 $3.96
22 1   STE-9-70-1523-00 Stearns Pressure Spring 
Part 9-70-1523-00 
aka 970152300 
[Ships from stock to 1 Week] 
[Updated 1-19]
- 0 $5.94
23 1   STE-9-70-1524-00 Stearns Pressure spring - 0 $3.70
24 1 11S STE-9-46-0010-00 Stearns Washer 
Part 9-70-1523-00 
aka 970152300 
Spring Washer 
Ships from Stock to 10 Days 
Dated 10-19
- 0 $2.98
25 1 17 STE-5-17-5011-00 Stearns 56,0,5&700 lever arm assembly - 0 $16.63
26 1 26 STE-9-29-4826-00 Stearns Pin 
Part 9-29-4826-00 
aka 929482600 
Dated 4-2020
- 0 $5.94
27 1 29A STE-8-094-503-00 Stearns Plunger Stop 
Part 8-094-503-00 
aka 809450300 
Ships from Stock to 10 Days 
Dated 1-2020
- 0 $5.95
28 1 126 STE-5-26-5020-00 Stearns 56K Support Plate 
Part 5-26-5020-00 
Support Plate and Spring Stud Assembly 
NEMA 4
- 0 $34.65
29 1 131 STE-9-29-4836-00 Stearns Pin 
Part 9-29-4836-00 
aka 929483600 
Ships in 
Dated
- 0 $5.94
30 1 142S STE-9-25-9013-00 Stearns Mounting screws - 0 $0.93
31 1 Z STE-5-96-5047-01 Stearns Solenoid Kit 
Part 5-96-5047-01 
# 4, Rev B only 
Dated 1/18
- 0 $158.40
32 1 12 STE-5-96-6407-05 Stearns Coil Kit 
Part 5-96-6407-05 
#4 Coil Kit 
115 / 230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4 Box
- 0 $492.80
33 1   STE-5-96-6409-05 Stearns Coil Kit 
Part 5-96-6409-05 
#4 Coil Kit 
230 / 460 Volt AC, 60 Hz 
Class "H" Insulation 
Dated 1/18 
(2LBS) H 4" L 5" W 4 Box
- 0 $506.88
34 1   STE-5-96-6401-05 Stearns Coil Kit 
Part 5-96-6401-05 
#4 Coil Kit 
115 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4 Box
- 0 $352.28
35 1   STE-5-96-6402-05 Stearns Coil Kit 
Part 5-96-6402-05 
#4 Coil Kit 
230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4 Box
- 0 $352.28
36 1   STE-5-96-6404-05 Stearns Coil Kit 
Part 5-96-6404-05 
#4 Coil Kit 
460 Volt AC 60 Hz 
Class "H" Insulation 
Ships in 7 to 10 days, WI 
Dated 1/18 
(2LBS) H 4" L 5" W 4 Box
- 0 $362.34
37 1   STE-5-96-6405-05 Stearns Coil Kit 
Part 5-96-6405-05 
#4 Coil Kit 
575 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4 Box
- 0 $352.28
38 1   STE-5-96-6457-05 Stearns Coil kit 
Part 5-96-6457-05 
#K4 Coil Kit 
115 / 230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 7/17
- 0 $466.81
39 1   STE-5-96-6459-05 Stearns Coil Kit 
Part 5-96-6459-05 
aka 596645905 
230 / 460 Volt 
K-4 Coil Kit 
Class "H" Insulation / High Heat 
Ships in 10 Days 
Dated 5-19
- 0 $499.45
40 1   STE-5-96-6451-05 Stearns Coil 
#K4 Coil Kit 
115 Volt AC, 60 Hz 
Class "H" Insulation 
4/17
- 0 $361.90
41 1   STE-5-96-6452-05 Stearns Coil Kit 
Part 5-96-6452-05 
K4 Coil Kit 
230 Volt AC 60 Hz 
Class "H" Insulation 
Ships in 10 days 
Dated 1/18
- 0 $372.24
42 1   STE-5-96-6454-05 Stearns Coil 
#K4 Coil Kit 
460 Volt AC, 60 Hz 
Class "H" Insulation 
8/16
- 0 $355.33
43 1   STE-5-96-6455-05 Stearns #K4 coil kit-575 Vac, 60 Hz, Cl. H - 0 $347.32
44 1   STE-5-96-6407-25 Stearns Coil Kit 
Part 5-96-6407-25 
#K4+ Coil Kit 
115 / 230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4 Box
- 0 $466.81
45 1   STE-5-96-6409-25 Stearns Coil Kit 
Part 5-96-6409-25 
#K4+ Coil Kit, Encapsulated 
230 / 460 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1-19 
(2LBS) H 4" L 5" W 4 Box
- 0 $499.45
46 1   STE-5-96-6401-25 Stearns Coil Kit 
Part 5-96-6401-25 
K4+ Coil Kit 
115 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4 Box
- 0 $352.28
47 1   STE-5-96-6402-25 Stearns Coil Kit 
Part 5-96-6402-25 
K4+ Coil Kit 
230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/1 
(2LBS) H 4" L 5" W 4 Box
- 0 $352.28
48 1   STE-5-96-6404-25 Stearns Coil Kit 
Part 5-96-6404-25 
K4+ Coil Kit 
460 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/1 
(2LBS) H 4" L 5" W 4 Box
- 0 $352.28
49 1   STE-5-96-6405-25 Stearns Coil Kit 
Part 5-96-6405-25 
K4+ Coil Kit 
575 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4 Box
- 0 $466.81
50 1   STE-5-96-6457-25 Call - 0 Call Call Call
51 1   STE-5-96-6459-25 Stearns M4+ coil kit-208-230/460 Vac, 60 Hz, Cl. H - 0 $448.03
52 1   STE-5-96-6451-25 Stearns M4+ coil kit-115 Vac, 60 Hz, Cl. H - 0 $347.32
53 1   STE-5-96-6452-25 Call - 0 Call Call Call
54 1   STE-5-96-6454-25 Stearns #M4+ coil kit-460 Vac, 60 Hz, Cl. H - 0 $347.32
55 1   STE-5-96-6455-25 Stearns No. M4+ Class 'H' coil kit 60 Hz 575 Vac - 0 $347.32
56 1 A STE-5-66-101X-00 Call - 0 Call Call Call
57 1 3 STE-5-66-8354-00 Stearns Disc kit 
Part 5-66-8354-00 
Stationary Disc Kit  
Dated 1/18
- 0 $53.47 Line #6 -
58 1 4 STE-5-66-8462-00 Stearns Disc 
Part 5-66-8462-00 
aka 566846200 
Friction Disc with Splined Hub 
Normally Ships from Stock 
Dated 1-2020 
(22LBS) H 4" L 10" W 10" Box
- 1 $129.69 Line #8 -
59 1 16 STE-5-16-5153-00 Call - 0 Call Call Call
60 1 Z STE-5-96-5047-01 Stearns Solenoid Kit 
Part 5-96-5047-01 
# 4, Rev B only 
Dated 1/18
- 0 $158.40 Line #31 -
61 1 12 STE-5-96-64XX-X5 Call - 0 Call Call Call
Easy Order Shortcuts
No Part
Number
Description Image Stock
Qty
Price
Each
Qty
Ord'd
Update
Cart
1 STE-1-056-812-00-BEF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,261.31
2 STE-1-056-812-00-BLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,261.31
3 STE-1-056-812-00-BNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,261.31
4 STE-1-056-812-00-BQF Stearns Disc Brake 
Part 1-056-812-00-BQF 
aka 105681200BQF 
Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard 
Ships in 2 Weeks, Racine WI 
Dated 2-1010
- 0 $1,938.29
5 STE-1-056-812-00-DMF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,261.31
6 STE-1-056-812-00-DNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,261.31
7 STE-1-056-822-00-BBF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,314.21
8 STE-1-056-822-00-BEF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,314.21
9 STE-1-056-822-00-BLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,314.21
10 STE-1-056-822-00-BNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,314.21
11 STE-1-056-822-00-BQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,314.21
12 STE-1-056-822-00-DLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,314.21
13 STE-1-056-822-00-DNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,314.21
14 STE-1-056-822-00-DQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,314.21
15 STE-1-056-832-00-BBF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
16 STE-1-056-832-00-BLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
17 STE-1-056-832-00-BQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
18 STE-1-056-832-00-CQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
19 STE-1-056-832-00-DEF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
20 STE-1-056-832-00-DLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
21 STE-1-056-832-00-DMF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
22 STE-1-056-832-00-DNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
23 STE-1-056-832-00-DQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,399.65
24 STE-1-056-842-00-BQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,481.02
25 STE-1-056-842-00-DLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,481.02
26 STE-1-056-842-00-DMF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,481.02
27 STE-1-056-842-00-DNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,481.02
28 STE-1-056-842-00-DQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,481.02
29 STE-1-056-842-00-FLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,664.13
30 STE-1-056-862-00-BLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [6] = 25 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,627.50
31 STE-1-056-862-00-BQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [6] = 25 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,627.50
32 STE-1-056-862-00-DLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [6] = 25 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,627.50
33 STE-1-056-862-00-DQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [6] = 25 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,627.50
Secure Online Order
 

 
Secure Online Order
 
6,655 part numbers available for
online order
 
Shopping Cart
Empty
Checkout is secure
 
All products are covered by a $1,000,000 liability insurance:
Click to view the Certificate
 

Products Available From Stock
Free shipping via UPS Ground (continental US only, motor freight excluded)
 
Web Site Features
 
Part Number Lookup
 
Enter at least three characters of a Stearns part number to retrive the list of all documents (such as specifications, manuals, guides, drawings, etc.) from our web site, referencing this part number:
 
Part Number:

 
Search scope:
This web site only
All BPI web sites
 
Formal PDF Quotation
 
To obtain an instant formal printable PDF quotation use shopping cart and select "View PDF Quote", instead of checking out. Click here for instructions.
 
Your shopping cart is kept intact and you can still check out at a later time.
About Stearns Products

 
About Stearns Products
 
Stearns is the leading manufacturer of spring-set electrically set motor brakes.
 
Choosing Stearns means you'll receive:
 
  • The broadest line of industrial brakes available from any
    single manufacturer.
  • The shortest lead times.
  • The best quality products to bring you maximum performance.
  • The most consistent and courteous customer service available in
    the power transmission business.
 
We always totally focused on the needs of its customers, setting the standard for brake and clutch quality, on-time performance, and commitment to innovative service.
 
Brakes

Motor Mounted Brakes

Double C-Face
Coupler Brakes

Division 1 Hazardous
Location Brakes

Division 2 Hazardous
Location Brakes

Encoder Brakes

Stainless Steel Motor
Mounted Brakes

Stainless Steel Double
C-Face Coupler Brakes

Marine, Maritime
and Navy Brakes

Servo and Stepper
Motor Brakes

Small Gearmotor Brakes

Small Gearmotor Brakes,
Quiet Operation

Small Gearmotor Brakes,
High Cycling Brake,
NEMA C-Face

Heavy Duty Electromagnetic
Spring Engaged Brakes

European Style
Direct Acting NEMA
C-Face Brakes

Brakes for Portal
Crane Applications

Quiet Brakes

Caliper Brakes

Bearing Supported
Thru-Shaft Brakes

MSHA Certified
Mining Brakes

Power On
Modular Brakes

Mechanical
Lockout Brakes
 

Brakes and
Replacement Parts
 
 
 
Clutches

Heavy Duty Electrically
Engaged Clutches
 

Heavy Duty Spring
Engaged Clutches
 

Power On Modular
Clutch Brakes
 

Power On Modular
Clutches
 

Small Industrial
Clutches
 
 
Solid State Switches for Single Phase Motors (SINPAC)

Switches for Capacitor Start
and Start, Run Motors
 

Switches for Capacitor
Start Motors
 

Switches for Capacitor
Start, Run Motors
 

Switches for Instant Reverse
Capacitor Start Motors
 

Switches for Split
Phase Motors
 
 
Miscellaneous Products

Foot Mounting Kits
 

Industrial Solenoids
 

Motor Frame Adapter Kits
 

Rectifiers
 

Installation and Maintenance Documentation
 
 
This web site is owned and operated by Brake Products, Inc.
Brake Products, Inc.   16751 Hilltop Park Place
  Chagrin Falls, Ohio 44023
  Phone: (440) 543-7962
  Fax:     (440) 543-7963
  Web:   www.brakeproducts.com
  Email: sales@brakeproducts.com
  Federal ID #: 34-1473351
  CAGE Code: 1QTP8
  DUNS# 14-748-2392
  Download: Form W-9