Web orders only - FREE shipping via UPS Ground (continental US only, motor freight excluded)
 
 
 
 
 
  BRAKE PRODUCTS
62,615 part numbers: Brake Wheels & Discontinued Brake Parts
  GEMCO
14,368 part numbers: Motion Control Products
 
  GLEASON
17,959 part numbers: Cable & Hose Management Systems
  AERO-MOTIVE
3,183 part numbers: Cable & Hose Management Systems
  CUTLER-HAMMER
6,359 part numbers: Electrical Control Products
 
 
 
 
 
  STEARNS
6,743 part numbers: Motor Mounted Brakes
  HUBBELL
8,387 part numbers: Electrical Control Products
  SUPERBOLT
117 part numbers: Fastening Solutions
  TELEMOTIVE
2,497 part numbers: Radio Remote Control
  RENOLD
406 part numbers: Mechanical Power Transmission Products
 
AUTOMATIC QUANTITY DISCOUNTS
 
BPI's web orders and web site generated PDF quotations now support quantity discount of up to 10%.
 
Quotation is valid for 30 days and can be immediately converted into an order.

 
 
CREDIT TERMS CHANGES
 
  1. Any account with invoices outstanding for more than 60 days will automatically be put on a credit hold.
  2. New customer payment terms are "Credit Card" only, full pre-pay. Credit Card information needs recorded at the time of order. Terms can be re-negotiated, upon successful payment.
 
Web: www.stearns-direct.com Email: sales@stearns-direct.com Phone: (888) 861-8777
 
Division 2 Hazardous Location Brakes: 56,800 (1-056-8XX) 56C-145TC
 
Series 56,800 (1-056-8XX)
Mounting Face: 56C-145TC
 

56,800
56C-145TC
 
Specifications:
(1-056-8XX)
 
Static Torque: 1.5 through 25 lb-ft.
Enclosure Material: Cast Iron.
Release Type: Side Lever, maintained with auto reset.
Enclosure Protection: IP 54.
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G.
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell. The acceptability of the brake and motor combination must be determined by Underwriters Laboratory.
Universal Mounting: Through 15 lb-ft. 20 and 25 lb-ft. supplied with springs for vertical modification.
Epoxy Encapsulated Coil Construction, with Class H Insulation.
NC Thermostat
Maximum speed: Horizontal 5000 rpm, Vertical 3600 rpm.
 
Replacement Parts for Series 56,800 for Class I & II, Division 2
Manual Adjust Brakes, Rev: A & B [P/N 8-078-905-18]


No Qty
Req'd
Item Part
Number
Description Picture Stock
Qty
Price
Each
Qty
Ord'd
Update
Cart
1 1 A STE-5-66-1015-00 Stearns Hardware Kit - side release - 0 $99.77
2 1 Not shown STE-5-63-0532-00 Stearns Plug/Gasket Kit 
Part 5-63-0532-00 
aka 563053200 
NEMA 4 
[Ships in 5 to 7 days] 
[Updated 1/19]
- 0 $31.54
3 1   STE-5-63-0534-00 Call - 0 Call Call Call
4 1 7 STE-5-07-5050-00 Call - 0 Call Call Call
5 1 5 STE-8-003-515-00 Call - 0 Call Call Call
6 1 3 STE-5-66-8354-00 Stearns Disc kit 
Part 5-66-8354-00 
566835400 
Stationary Disc Kit  
Ships from Stock to 2 Weeks 
Dated 11-2022
- 0 $71.29
7 1 Not shown STE-5-63-0525-00 Stearns Spring Kit 
Part 5-63-0525-00 
aka 563052500 
56 Plug Wire Nut & Vertical Spring Kit-Open 
Ships from Stock to 5 Days 
Dated 1-2020
- 0 $58.27
8 1 4 STE-5-66-8462-00 Stearns Disc 
Part 5-66-8462-00 
566846200 
Friction Disc with Splined Hub 
Normally Ships from Stock 
Dated 11-2022 
(22LBS) H 4" L 10" W 10" Box
- 0 $130.70
9 1 21 STE-9-62-8026-00 Stearns Thermostat - 0 $279.34
10 1 16 STE-5-16-5151-00-01B Stearns 56 spln. hub 5/8 bore 1 disc - 0 $89.79
11 1   STE-5-16-5151-00-01D Stearns 56 spln. hub 7/8 bore 1 disc - 0 $89.79
12 1   STE-5-16-5151-00-01E Stearns 56 spln. hub 1-1/8 bore 1 disc - 0 $89.79
13 1   STE-5-16-5153-00-01B Stearns 56 spln. hub 5/8 bore 2&3 disc - 0 $84.80
14 1   STE-5-16-5153-00-01D Stearns Hub 
Part 5-16-5153-00-01D 
56K Splined Hub 
0.9875 Inch Bore 
2 & 3 Disc 
Ships in 10 Days 
Dated 12-19
- 0 $95.69
15 1   STE-5-16-5153-00-01E Stearns 56 spln. hub 1-1/8 bore 2&3 disc - 0 $109.74
16 1 2 STE-5-02-5049-00 Stearns End Plate / Seal Assembly 
Part STE-5-02-5049-00 
56,800 Div. 2, 1 Disc 
End Plate / Seal Assmbly 
Dated 1/17
- 0 $706.86
17 1   STE-5-02-5050-00 Stearns End Plate Seal Assembly 
Part STE-5-02-5050-00 
56,800 Div. 2, 2 & 3 Disc 
Endpalte / Seal Assembly 
Dated 1/17
- 0 $727.65
18 1 6 STE-8-006-501-00 Stearns Bearing 
Part 8-006-501-00 
800650100 
Sleeve Bearing 
Oilite 
0.31 Inch Diameter  
0.59 Inch Long 
Ships in 1 Week 
Dated 10-2022
- 0 $7.92
19 1 8 STE-8-008-504-01 Stearns Lever 
Part 8-008-504-01 
800850401 
56 Solenoid Lever 
Aluminum W/Fin 
Ships in 1 to 2 Weeks, Racine WI 
Dated 01-2024 
(1LB) H 4" L 5" W 4" Box
- 0 $64.45
20 1 8R STE-9-03-0057-00 Stearns Retaining Ring 
Part 9-03-0057-00 
903005700 
Ships in 1 Week, WI Racine 
Dated 07-2023
- 0 $3.22
21 1 8W STE-9-45-0168-00 Stearns Lock Washer 
Part 9-45-0168-00 
945016800 
Dated 03-2023
- 0 $5.00
22 1 11N STE-9-40-3928-00 Stearns Nut 
Part 9-40-3928-00 
940392800 
Ships from Stock 
Dated 02-2021 
(1LB) H 4" L 6" W 4" Box
- 0 $6.42
23 1 10 STE-9-17-8420-00 Stearns Cap Screw 
Dated 02-2021
- 0 $13.37
24 1 11 STE-9-70-1215-00 Stearns Pressure Spring 
Part 9-70-1215-00 
Ships in 
Dated 10/18
- 0 $4.28
25 1   STE-9-70-1523-00 Stearns Pressure Spring 
Part 9-70-1523-00 
970152300 
Ships from stock to 1 Week 
Dated 01-2021 
(1LB) H 4" L 6" W 4" Box
- 0 $6.42
26 1   STE-9-70-1524-00 Stearns Pressure Spring - 0 $6.42
27 1 11S STE-9-46-0010-00 Stearns Washer 
Part 9-70-1523-00 
aka 970152300 
Spring Washer 
Ships from Stock to 10 Days 
Dated 02-2021
- 0 $3.22
28 1 17 STE-5-17-5011-00 Stearns 56,0,5&700 lever arm assembly - 0 $17.96
29 1 26 STE-9-29-4826-00 Stearns Pin 
Part 9-29-4826-00 
929482600 
Ships in 1 Week 
Dated 03-2023
- 0 $9.06
30 1 29A STE-8-094-503-00 Stearns Plunger Stop 
Part 8-094-503-00 
809450300 
10560468 
Plunger Stop, HSG Bumper 
Ships in 10 Days 
Dated 09-2023 
(1LB)
- 0 $9.50
31 1 126 STE-5-26-5020-00 Stearns 56K Support Plate 
Part 5-26-5020-00 
Support Plate and Spring Stud Assembly 
NEMA 4
- 0 $37.42
32 1 131 STE-9-29-4836-00 Stearns Pin 
Part 9-29-4836-00 
aka 929483600 
Ships in 
Dated
- 0 $6.42
33 1 142S STE-9-25-9013-00 Stearns Mounting screws - 0 $1.00
34 1 Z STE-5-66-5047-00 Stearns Solenoid Kit #4 
Part 5-66-5047-00 
566504700 
#4 AC Solenoid Kit 
Series 56,700 
Ships in 
Dated 01-2024
- 0 $232.89
35 1 12A STE-5-96-6407-05 Stearns Coil Kit 
Part 5-96-6407-05 
#4 Coil Kit 
115 / 230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4" Box
- 0 $532.22
36 1   STE-5-96-6409-05 Stearns Coil Kit 
Part 5-96-6409-05 
#4 Coil Kit 
230 / 460 Volt AC, 60 Hz 
Class "H" Insulation 
Dated 1/18 
(2LBS) H 4" L 5" W 4" Box
- 0 $547.43
37 1   STE-5-96-6401-05 Stearns Coil Kit 
Part 5-96-6401-05 
#4 Coil Kit 
115 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4" Box
- 0 $380.46
38 1   STE-5-96-6402-05 Stearns Coil Kit 
Part 5-96-6402-05 
#4 Coil Kit 
230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4" Box
- 0 $380.46
39 1   STE-5-96-6404-05 Stearns Coil Kit 
Part 5-96-6404-05 
#4 Coil Kit 
460 Volt AC 60 Hz 
Class "H" Insulation 
Ships in 7 to 10 days, WI 
Dated 1/18 
(2LBS) H 4" L 5" W 4" Box
- 2 $391.33
40 1   STE-5-96-6405-05 Stearns Coil Kit 
Part 5-96-6405-05 
#4 Coil Kit 
575 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4" Box
- 0 $380.46
41 1   STE-5-96-6457-05 Stearns Coil kit 
Part 5-96-6457-05 
#K4 Coil Kit 
115 / 230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 7/17
- 0 $504.15
42 1   STE-5-96-6459-05 Stearns Coil Kit K4 
Part 5-96-6459-05  
596645905 
230 - 460 Volt 
K-4 Coil Kit 
Class "H" Insulation - High Heat 
Ships in 2 Weeks, WI 
Dated 04-2021 
(2LBS) H 4" L 6" W 4" Box
- 2 $562.56
43 1   STE-5-96-6451-05 Stearns Coil K4 
Part 5-96-6451-05 
596645105 
#K4 Coil Kit 
115 Volt AC, 60 Hz 
Class "H" Insulation 
Ships in 
Dated
- 0 $390.85
44 1   STE-5-96-6452-05 Stearns Coil Kit 
Part 5-96-6452-05 
K4 Coil Kit 
230 Volt AC 60 Hz 
Class "H" Insulation 
Ships in 10 days 
Dated 1/18
- 0 $402.02
45 1   STE-5-96-6454-05 Stearns Coil 
Part 5-96-6454-05 
596645405 
#K4 Coil Kit 
460 Volt AC 60 Hz 
Class "H" Insulation 
Ships in  
Dated 08-2020
- 0 $422.33
46 1   STE-5-96-6455-05 Stearns Coil Kit #K4 
Part 5-96-6455-05 
596645505 
Coil Kit # 4 
575 Volt AC 60 Hz  
Class "H" Coil Insulation 
Ships in 2 Weeks 
Dated 12-2020
- 0 $418.06
47 1   STE-5-96-6407-25 Stearns Coil Kit 
Part 5-96-6407-25 
#K4+ Coil Kit 
115 / 230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4" Box
- 0 $504.15
48 1   STE-5-96-6409-25 Stearns Coil Kit 
Part 5-96-6409-25 
#K4+ Coil Kit, Encapsulated 
230 / 460 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1-19 
(2LBS) H 4" L 5" W 4" Box
- 0 $539.41
49 1   STE-5-96-6401-25 Stearns Coil Kit 
Part 5-96-6401-25 
K4+ Coil Kit 
115 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4" Box
- 0 $380.46
50 1   STE-5-96-6402-25 Stearns Coil Kit 
Part 5-96-6402-25 
K4+ Coil Kit 
230 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/1 
(2LBS) H 4" L 5" W 4" Box
- 0 $380.46
51 1   STE-5-96-6404-25 Stearns Coil Kit 
Part 5-96-6404-25 
K4+ Coil Kit 
460 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/1 
(2LBS) H 4" L 5" W 4" Box
- 0 $380.46
52 1   STE-5-96-6405-25 Stearns Coil Kit 
Part 5-96-6405-25 
K4+ Coil Kit 
575 Volt AC 60 Hz 
Class "H" Insulation 
Dated 1/17 
(2LBS) H 4" L 5" W 4" Box
- 0 $504.15
53 1   STE-5-96-6457-25 Call - 0 Call Call Call
54 1   STE-5-96-6459-25 Stearns M4+ coil kit-208-230/460 Vac, 60 Hz, Cl. H - 0 $483.87
55 1   STE-5-96-6451-25 Stearns M4+ coil kit-115 Vac, 60 Hz, Cl. H - 0 $375.11
56 1   STE-5-96-6452-25 Call - 0 Call Call Call
57 1   STE-5-96-6454-25 Stearns #M4+ coil kit-460 Vac, 60 Hz, Cl. H - 0 $375.11
58 1   STE-5-96-6455-25 Stearns No. M4+ Class 'H' coil kit 60 Hz 575 Vac - 0 $375.11
59 1 A STE-5-66-101X-00 Call - 0 Call Call Call
60 1 3 STE-5-66-8354-00 Stearns Disc kit 
Part 5-66-8354-00 
566835400 
Stationary Disc Kit  
Ships from Stock to 2 Weeks 
Dated 11-2022
- 0 $71.29 Line #6 -
61 1 4 STE-5-66-8462-00 Stearns Disc 
Part 5-66-8462-00 
566846200 
Friction Disc with Splined Hub 
Normally Ships from Stock 
Dated 11-2022 
(22LBS) H 4" L 10" W 10" Box
- 0 $130.70 Line #8 -
62 1 16 STE-5-16-515X-00 Call - 0 Call Call Call
63 1 Z STE-5-66-5047-00 Stearns Solenoid Kit #4 
Part 5-66-5047-00 
566504700 
#4 AC Solenoid Kit 
Series 56,700 
Ships in 
Dated 01-2024
- 0 $232.89 Line #34 -
64 1 12A STE-5-96-64XX-X5 Call - 0 Call Call Call
Easy Order Shortcuts
No Part
Number
Description Image Stock
Qty
Price
Each
Qty
Ord'd
Update
Cart
1 STE-1-056-812-00-BEF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,362.22
2 STE-1-056-812-00-BLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,362.22
3 STE-1-056-812-00-BNF Stearns Disc Brake Assembly 
Part 1-056-812-00-BNF  
105681200BNF 
Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard 
Ships in 3 to 4 Weeks 
Dated 06-2021
- 0 $2,245.63
4 STE-1-056-812-00-BQF Stearns Disc Brake Assembly 
Part 1-056-812-00-BQF 
aka 105681200BQF 
Series 56,800 (1-056-8XX) Brake, Cast Iron 
Division 2 Hazardous Location 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque 3 LB FT  
Enclosure IP 54 
Hub [B] = Bore: 5/8 
Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard 
Ships in 2 Weeks, Racine WI 
Dated 09-2020
- 0 $2,093.35
5 STE-1-056-812-00-DMF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,362.22
6 STE-1-056-812-00-DNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [1] = 3 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,362.22
7 STE-1-056-822-00-BBF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,419.35
8 STE-1-056-822-00-BEF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,419.35
9 STE-1-056-822-00-BLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,419.35
10 STE-1-056-822-00-BNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,419.35
11 STE-1-056-822-00-BQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,419.35
12 STE-1-056-822-00-DLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,419.35
13 STE-1-056-822-00-DNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,419.35
14 STE-1-056-822-00-DQF Stearns Disc Brake Assembly 56,8 
Part 1-056-822-00-DQF 
105682200DQF 
Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [2] = 6 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard 
Ships in 2 to 3 Weeks, WI 
Dated 07-2021
- 0 $2,120.49
15 STE-1-056-832-00-BBF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,511.62
16 STE-1-056-832-00-BLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,511.62
17 STE-1-056-832-00-BQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,511.62
18 STE-1-056-832-00-CQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,511.62
19 STE-1-056-832-00-DEF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,511.62
20 STE-1-056-832-00-DLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,511.62
21 STE-1-056-832-00-DMF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,511.62
22 STE-1-056-832-00-DNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,511.62
23 STE-1-056-832-00-DQF Stearns Disc Brake Assembly 56.8 
Part 1-056-832-00-DQF  
105683200DQF 
Series 56,800 
Brake, Cast Iron, Division 2 Hazardous Location 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [3] = 10 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard 
Ships in 6 Weeks, WI Racine 
Dated 11-2023
- 0 $2,568.92
24 STE-1-056-842-00-BQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,599.50
25 STE-1-056-842-00-DLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,599.50
26 STE-1-056-842-00-DMF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,599.50
27 STE-1-056-842-00-DNF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,599.50
28 STE-1-056-842-00-DQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,599.50
29 STE-1-056-842-00-FLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [4] = 15 
Enclosure [2] = IP 54 
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,797.26
30 STE-1-056-862-00-BLF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [6] = 25 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,757.70
31 STE-1-056-862-00-BQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [6] = 25 
Enclosure [2] = IP 54 
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,757.70
32 STE-1-056-862-00-DLF SStearns Disc Brake Assembly 
Part 1-056-862-00-DLF 
105685200DLF 
Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [6] = 25 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard 
Ships in 5 to 8 Weeks, WI 
Dated 11-2022
- 0 $2,641.28
33 STE-1-056-862-00-DQF Stearns Series 56,800 (1-056-8XX) Brake, Cast Iron, Division 2 Hazardous Location: 
Mounting Requirements: 1-056-8X2 Series Hazardous Location Motor Mounted Brake is recommended for mounting close coupled to the motor end bell 
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ 
Enclosure Protection: IP 54 
Release Type: Side Lever, maintained with auto reset 
Epoxy Encapsulated Coil Construction, with Class H Insulation 
NC Thermostat 
Certified: UL Listed, File E 14893 for Class 1, Division 2, Groups A, B, C, D, and Class II, Division 2, Groups F and G 
Nominal Static Torque (lb-ft) [6] = 25 
Enclosure [2] = IP 54 
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) 
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
- 0 $1,757.70
Secure Online Order
 

 
Secure Online Order
 
6,743 part numbers available for
online order
 
Shopping Cart
Empty
Checkout is secure
 
 

Products Available From Stock
Free shipping via UPS Ground (continental US only, motor freight excluded)
 
Web Site Features
 
Part Number Lookup
 
Enter at least three characters of a Stearns part number to retrive the list of all documents (such as specifications, manuals, guides, drawings, etc.) from our web site, referencing this part number:
 
Part Number:

 
Search scope:
This web site only
 
Formal PDF Quotation
 
To obtain an instant formal printable PDF quotation use shopping cart and select "View PDF Quote", instead of checking out. Click here for instructions.
 
Your shopping cart is kept intact and you can still check out at a later time.
About Stearns Products

 
About Stearns Products
 
Stearns is the leading manufacturer of spring-set electrically set motor brakes.
 
Choosing Stearns means you'll receive:
 
  • The broadest line of industrial brakes available from any
    single manufacturer.
  • The shortest lead times.
  • The best quality products to bring you maximum performance.
  • The most consistent and courteous customer service available in
    the power transmission business.
 
We always totally focused on the needs of its customers, setting the standard for brake and clutch quality, on-time performance, and commitment to innovative service.
 
Brakes

Motor Mounted Brakes

Double C-Face
Coupler Brakes

Division 1 Hazardous
Location Brakes

Division 2 Hazardous
Location Brakes

Encoder Brakes

Stainless Steel Motor
Mounted Brakes

Stainless Steel Double
C-Face Coupler Brakes

Marine, Maritime
and Navy Brakes

Servo and Stepper
Motor Brakes

Small Gearmotor Brakes

Small Gearmotor Brakes,
Quiet Operation

Small Gearmotor Brakes,
High Cycling Brake,
NEMA C-Face

Heavy Duty Electromagnetic
Spring Engaged Brakes

European Style
Direct Acting NEMA
C-Face Brakes

Brakes for Portal
Crane Applications

Quiet Brakes

Caliper Brakes

Bearing Supported
Thru-Shaft Brakes

MSHA Certified
Mining Brakes

Power On
Modular Brakes

Mechanical
Lockout Brakes
 

Brakes and
Replacement Parts
 
 
 
Clutches

Heavy Duty Electrically
Engaged Clutches
 

Heavy Duty Spring
Engaged Clutches
 

Power On Modular
Clutch Brakes
 

Power On Modular
Clutches
 

Small Industrial
Clutches
 
 
Solid State Switches for Single Phase Motors (SINPAC)

Switches for Capacitor Start
and Start, Run Motors
 

Switches for Capacitor
Start Motors
 

Switches for Capacitor
Start, Run Motors
 

Switches for Instant Reverse
Capacitor Start Motors
 

Switches for Split
Phase Motors
 
 
Miscellaneous Products

Foot Mounting Kits
 

Industrial Solenoids
 

Motor Frame Adapter Kits
 

Rectifiers
 

Installation and Maintenance Documentation
 
 
This web site is owned and operated by Brake Products, Inc.
Brake Products, Inc.   16751 Hilltop Park Place
  Chagrin Falls, Ohio 44023
  Phone: (440) 543-7962
  Fax:     (440) 543-7963
  Web:   www.brakeproducts.com
  Email: sales@brakeproducts.com
  Federal ID #: 34-1473351
  CAGE Code: 1QTP8
  DUNS# 14-748-2392
  Download: Form W-9
  ACH Form: Word   /   PDF
Supplier of Industrial Brake Parts Since 1985