Database Lookup:
By Part Number
By Description
Total 6745 part numbers listed in this database. Shown in 212 pages by 32 items.
Pages: Prev , Next , 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59
Part Number
Product Category
Description
Image
Stock Qty
Weight (lbs.)
Price (US$)
Order Quantity
STE-1-056-566-00-DUF
Stearns Parts
Stearns Series 56,500 (1-056-5XX) Brake, Stamped Steel Housing, Cast Iron Endplate: Release Type: Knob, Maintained with Automatic Reset Mounting: Fanguard-mounted brakes requiring IP 54 or IP 55 protection Mounting Face: NEMA 182TC and 184TC 8.5" AK, 7.25" AJ Enclosure Protection: IP 23, 54 & 55 Nominal Static Torque (lb-ft) [6] = 25 Enclosure [6] = IP 54 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [U] = N/A Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,371.01
STE-1-056-611-00-BBF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,054.62
STE-1-056-611-00-BNF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,054.62
STE-1-056-611-00-BQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,054.62
STE-1-056-611-00-DQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,054.62
STE-1-056-612-00-BBF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,173.27
STE-1-056-612-00-BMF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,173.27
STE-1-056-612-00-BNF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,173.27
STE-1-056-612-00-BQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,173.27
STE-1-056-612-00-DLF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,173.27
STE-1-056-612-00-DNF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,173.27
STE-1-056-612-00-DQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,173.27
STE-1-056-614-00-BNF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [4] = IP 57 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,239.18
STE-1-056-614-00-BPF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [4] = IP 57 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,239.18
STE-1-056-614-00-BQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [4] = IP 57 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,239.18
STE-1-056-616-00-BUF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [1] = 3 Enclosure [6] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [U] = N/A Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,436.93
STE-1-056-621-00-BLF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,111.75
STE-1-056-621-00-BNF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,111.75
STE-1-056-621-00-BQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,111.75
STE-1-056-621-00-DPF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,111.75
STE-1-056-622-00-BLF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,230.39
STE-1-056-622-00-BNF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,230.39
STE-1-056-622-00-BPF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,230.39
STE-1-056-622-00-BQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,230.39
STE-1-056-622-00-CQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [2] = IP 56 Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,230.39
STE-1-056-622-00-DNF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,230.39
STE-1-056-622-00-DQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,230.39
STE-1-056-622-00-EQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [2] = IP 56 Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,230.39
STE-1-056-624-00-BLF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [4] = IP 57 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,296.31
STE-1-056-624-00-BNF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [4] = IP 57 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,296.31
STE-1-056-624-00-BQF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [2] = 6 Enclosure [4] = IP 57 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,296.31
STE-1-056-631-00-BLF
Stearns Parts
Stearns Series 56,600 (1-056-6XX) Brake, Cast Iron enclosure: Release Type: Internal Lever, Non-Maintained Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection Mounting Face: NEMA 56C, 143TC and 145TC, 4.5" AK, 5.88" AJ Visual Wear Indicator Enclosure Protection: IP 23, 56 & 57 Nominal Static Torque (lb-ft) [3] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
0.00
1,199.63