Database Lookup:
By Part Number
By Description
Total 6745 part numbers listed in this database. Shown in 212 pages by 32 items.
Pages: Prev , Next , 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82
Part Number
Product Category
Description
Image
Stock Qty
Weight (lbs.)
Price (US$)
Order Quantity
STE-1-065-351-05-DQC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [C] = Form 3
-
0
0.00
2,456.40
STE-1-065-351-05-DRB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz Lead Wire Position [B] = Form 2
-
0
0.00
2,456.40
STE-1-065-351-09-BFB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
2,895.82
STE-1-065-351-09-BLB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
2,895.82
STE-1-065-351-09-BNB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Lead Wire Position [B] = Form 2
-
0
0.00
2,895.82
STE-1-065-351-09-BQB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
2,895.82
STE-1-065-351-09-BQC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [C] = Form 3
-
0
0.00
2,895.82
STE-1-065-351-09-DBB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz Lead Wire Position [B] = Form 2
-
0
0.00
2,895.82
STE-1-065-352-07-BQB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [5] = 10 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
3,071.59
STE-1-065-352-07-BQC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [5] = 10 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [C] = Form 3
-
0
0.00
3,071.59
STE-1-065-361-05-039
Stearns Parts
Stearns Brake 1-065-361-05-039 15 Foot LB 460 Volt AC Internal Heater Zinc Primer Centralizing Spring 0.875 / 7/8 Inch Hub Bore 3 Weeks to Ship 2/16
-
0
0.00
3,484.64
STE-1-065-361-05-BFC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz) Lead Wire Position [C] = Form 3
-
0
0.00
2,561.86
STE-1-065-361-05-BNC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Lead Wire Position [C] = Form 3
-
0
0.00
2,561.86
STE-1-065-361-05-BQB
Stearns Parts
Stearns Disc Brake Part 1-065-361-05-BQB Series 65,300 / 1-065-3XX-05 Brake Division I Hazardous Location NEMA 7, 9 Enclosure Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake Is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D Class II, Group E, F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction Class H Coil Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque 6 = 15 LB FT Enclosure 1 = IP 23 Hub [B] = Bore 5/8 with a 3/16 x 3/32 Keyway Standard AC Voltage Rating [Q] = 208-230/460 60 Hz / 190/380 50 Hz Lead Wire Position [B] = Form 2 Ships in 2 weeks, WI Dated 5/18
-
0
0.00
2,691.72
STE-1-065-361-05-BQC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [C] = Form 3
-
0
0.00
2,561.86
STE-1-065-361-05-CPB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz Lead Wire Position [B] = Form 2
-
0
0.00
2,561.86
STE-1-065-361-05-CQB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
2,561.86
STE-1-065-361-05-DEB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz Lead Wire Position [B] = Form 2
-
0
0.00
2,561.86
STE-1-065-361-05-DFB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
2,561.86
STE-1-065-361-05-DLB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
2,561.86
STE-1-065-361-05-DLC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [C] = Form 3
-
0
0.00
2,561.86
STE-1-065-361-05-DNB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Lead Wire Position [B] = Form 2
-
0
0.00
2,561.86
STE-1-065-361-05-DPB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz Lead Wire Position [B] = Form 2
-
0
0.00
2,561.86
STE-1-065-361-05-DQB
Stearns Parts
Stearns Disc Brake Assembly 65,3 Part 1-065-361-05-DQB 10653605DQB Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9. Enclosure Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, For Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 Ships in 3 Weeks, WI Dated 07-2021
-
0
0.00
3,587.32
STE-1-065-361-05-DQC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [C] = Form 3
-
0
0.00
2,561.86
STE-1-065-361-05-LBB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [L] = N/A Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz Lead Wire Position [B] = Form 2
-
0
0.00
2,847.47
STE-1-065-361-05-LLB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [L] = N/A Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
2,847.47
STE-1-065-361-05-LQB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-05) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-05 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL, File E-14893, for Class I, Group C and D and Class II, Group E, F and G, Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [L] = N/A Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
2,847.47
STE-1-065-361-09-BQB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
3,001.28
STE-1-065-362-07-DLC
Stearns Parts
Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [6] = 15 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [C] = Form 3
-
0
0.00
3,203.41
STE-1-065-362-07-DQB
Stearns Parts
Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [6] = 15 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2
-
0
0.00
3,203.41
STE-1067F
Stearns Parts
Stearns Receiver Card for a Type HS Metal Detector
-
0
0.00
415.13